Pacific Security System

MANILA OFFICE:
G/F Mary Bachrach Building corner 25th
and Railroad Streets Port Area,
Manila Philippines 1018
Tel No: +63 2 8527.7171
Email Add:sales@vingcardph.com
CEBU OFFICE:
2/F RJM Building Unit 1-4 Osmeña Blvd.
Capitol Site Cebu City, Philippines 6000
Sales Mobile No: 0999-884-6450
Technical Mobile No: 0908-873-5465 / 0999-885-7351
Email Add:cebu@vingcardph.com
MANILA OFFICE: G/F Mary Bachrach Building corner 25th and Railroad Streets Port Area, Manila Philippines 1018
Tel No: +63 2 8527.7171
Fax No: +63 2 8526.7181
Email Add:sales@vingcardph.com
CEBU OFFICE: 2/F RJM Building Unit 1-4 Osmeña Blvd. Capitol Site Cebu City, Philippines 6000
Tel No: 0908-873-5465 / 0999-885-7531
Fax No: +63 2 8526.7181 Email Add:cebu@vingcardph.com

MANILA OFFICE: G/F Mary Bachrach Building corner 25th and Railroad Streets Port Area, Manila Philippines 1018

Tel No: +63 2 8527.7171

Fax No: +63 2 8526.7181

Email Add:sales@vingcardph.com

CEBU OFFICE: 2/F RJM Building Unit 1-4 Osmeña Blvd. Capitol Site Cebu City, Philippines 6000
Tel No: 0908-873-5465 / 0999-885-7531
Fax No: +63 2 8526.7181
Email Add:cebu@vingcardph.com

ENERGY CONTROL UNIT

The intelligent choice to save money
ASSA ABLOY Hospitality offers a complete range of in-room Energy Control Units, the perfect combination to provide in-room comfort to your guests and saving energy and money when the guests are not in their room.

FEATURES

: Disconnects electrical equipment and air conditioning when   guests are outside the room, thus saving money.
: Courtesy timer for guests when removing the keycard from the   Energy Control Unit.
: Simple installation.

ENERGY CONTROL UNIT

The intelligent choice to save money
ASSA ABLOY Hospitality offers a complete range of in-room Energy Control Units, the perfect combination to provide in-room comfort to your guests and saving energy and money when the guests are not in their room.

FEATURES

: Disconnects electrical equipment and air conditioning when   guests are outside the room, thus saving money.
: Courtesy timer for guests when removing the keycard from the   Energy Control Unit.
: Simple installation.

STANDARD
INTELLIGENT MAGNETIC STRIPE
INTELLIGENT RFID
Descriptions:
Mechanical temporized energy saver.
Only operates with hotel specific magnetic striped keycards.
Only operates with hotel specific RFID keycards.
Guest/Staff keycard
It prevents hotel staff from using certain electrical equipment in the room (air conditioning, TV, phone etc.) while cleaning the rooms.
It prevents hotel staff from using certain electrical equipment in the room (air conditioning, TV, phone etc.) while cleaning the rooms.
Voltage:
110/220 Vac. Tolerance 10 %.
110/220 Vac. Tolerance 10 %.
110/220 Vac. Tolerance 10 %.
Consumption:
Nominal of 10 m/Amp. Max. of 20 m/Amp.
Nominal of 10 m/Amp. Max. of 20 m/Amp.
Frequency:
50-60 Hz
50-60 Hz
50 – 60 Hz
Output relay:
1 relay. Power of cutting: 10 A, 250 V-, cos = 1
6 A, 250 V-, cos = 0,6
Incandescent max. load 8 A – Halogen max. load 8 A
2 relays. One according to the power supply and other potential free.
Power of cutting: 10 A, 250 V-, cos = 1
6 A, 250 V-, cos = 0,6
Incandescent max. load 8 A – Halogen max. load 8 A
2 relays. One according to the power supply and other potential free.>br> Power of cutting: 10 A, 250 V-, cos = 1
6 A, 250 V-, cos = 0,6
Incandescent max. load 8 A – Halogen max. load 8 A
Size mm: inch:
Height 132 • Width 97 • Depth 35
Height 5,20 • Width 3,82 • Depth 1,38
Height 132 • Width 97 • Depth 35
Height 5,20 • Width 3,82 • Depth 1,38
Height 132 • Width 97 • Depth 35
Height 5,20 • Width 3,82 • Depth 1,38
Weight grams ponds
186 grams 0,41
210 grams 0,46
210 grams 0,46
Box:
FIREPROOF material (BG3(H)) according to norm UL 94 V-0.
FIREPROOF material (BG3(H)) according to norm UL 94 V-0.
FIREPROOF material (BG3(H)) according to norm UL 94 V-0.